CRIS

Permanent URI for this communityhttps://cris-udd.scimago.es/handle/123456789/1

Browse

Search Results

Now showing 1 - 2 of 2
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Fire Performance of Recycled Aggregate Concrete: Experimental Assessment of Compressive Strength and Physical Deterioration at Elevated Temperatures
    (2026)
    Gabriela Peñafiel
    ;
    Carlos Navarro
    ;
    Santiago Medina Robalino
    ;
    ;
    Bernarda Abril
    Concrete remains one of the most widely utilized construction materials, valued particularly for its exceptional compressive strength. However, exposure to fire can compromise both its internal microstructure and external integrity. This research investigates the behavior of concrete manufactured with recycled concrete coarse aggregate (RCA) derived from construction waste, aiming to establish experimental evidence of fire’s impact on compressive strength. We employed the Optimal Density Method to design mix proportions targeting 24 MPa compressive strength. The experimental program comprised 45 cylindrical samples distributed across three replacement levels: 0%, 15%, and 30% natural aggregate substitution with RCA. Following 28 days of curing, samples underwent direct fire exposure in a melting furnace. Temperature progression was monitored using a pyrometer, ranging from ambient (0 °C) through 250 °C, 400 °C, 600 °C, to 800 °C, with controlled exposure duration at each level. Three samples were tested at each temperature. After fire exposure, samples were cooled for 24 h at ambient temperature before compression testing. The densities of the fresh specimens were determined to be 2254.06 kg/m3 for HS-0AR%, 2210.09 kg/m3 for HS-15AR%, and 2180.85 kg/m3 for HS-30AR%, with a percentage density variation with respect to HS-0AR% of 1.95% and 3.25%, respectively. Finally, in relation to the compressive strength of concrete, a reduction of 4.34% was observed for 15% AGR and 5.72% for 30%, suggesting that the variations may be due to factors such as the water/cement ratio, the quality of the aggregate, and the curing conditions of concrete. In addition, several pathologies were observed, such as cracking, fissures, color changes, and spalling.
      3
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Experimental analysis of ecuadorian adobe reinforced with natural fibers
    (2025)
    Carlos Pinto-Almeida
    ;
    ;
    Nahomy Anahí Armas-Robalino
    ;
    Bianca Christina Cáceres
    ;
    Juan Carlos Cajas-Corrales
    Introduction: In Latin America, the use of adobe as a building material remains highly relevant due to its low cost, local availability, and low environmental impact. Nevertheless, its limited mechanical strength and lack of standardization constrain broader implementation in contemporary architecture. Methods: This study addresses that gap by experimentally evaluating the mechanical performance of adobe blocks stabilized with fine sand and wild straw, produced with red clay from Puyo (Ecuador). The research followed an applied, descriptive–comparative design encompassing material characterization, a 30-day natural curing process, and compressive strength testing using a SHIMADZU Concreto 2000X machine. Results: The stabilized blocks achieved an average compressive strength of 9.63 kg/cm² (≈ 0.94 MPa), a mean displacement of 2.98 mm, and a maximum load of 14.16 kN, values that confirm their suitability for low-rise load-bearing structures. The inclusion of wild straw improved ductility, internal cohesion, and post-fracture integrity, while controlled shade drying minimized microcracking. Compared with traditional handmade bricks (31 kg/cm²), the material showed lower strength but significantly higher environmental and economic sustainability. Conclusion: The results provide empirical indicators to guide the standardization and scalability of stabilized adobe as a low-carbon, structurally viable alternative for rural and peri-urban housing in seismic regions.
      23